Cloud Fieldbus UI: Validation of fragment / series names

Our Customer TT-Control has following issue: Incident: 5428979 Basically the problem of TTC is that their customers uses spaces when they define device types in holding registers. The problem results in empty reports. TTC asks if it is possible to...
Guest about 4 years ago in Cumulocity IoT Device Mgmt. & Connectivity / Cloud Fieldbus 2 Future consideration

Filter events by time and not just by date

Machines from Weber Maschinenbau create thousands of events per day representing state changes of the machines. In Device Management when looking at the event list, it is only possible to filter for full days instead of timestamps like it is possi...
Guest over 4 years ago in Cumulocity IoT Device Mgmt. & Connectivity 0 Likely to support/improve

make simulator name not editable

https://migration105-ramazure_02.ram.m2m.telekom.com/apps/devicemanagement/index.html#/simulators/224373/instructions V 10.5.0.7 login: c8y / Test1234 steps: edit existing simulator > change simulator name and add some new instructions expected...
Guest over 4 years ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Already supported

Cloud Fieldbus support for float32 via Modbus

At the moment, the Cloud Fieldbus feature and the Modbus Linux agent only support integer measurements. A number of Modbus devices now actually support float values (typically 32Bit IEEE-754) which currently have to be converted manually using a m...
Guest over 4 years ago in Cumulocity IoT Device Mgmt. & Connectivity 0 Unlikely to support

Issse with Device Management App: Tree View is not readable

If you have large data models with groups of large hirarchical layers, the treeview on the left sind eof the DevMgmt App is clipping text so you cannot read it anymore. Ask Gerhard Krause or Kai Reinhardt or Dirk Siebert(alls SAG staff) about more...
Guest over 4 years ago in Cumulocity IoT Device Mgmt. & Connectivity 0 Unlikely to support

LWM2M custom decoder for a whole object

For some objects, it is more efficient for a device to report whole object in one message. Therefore it would be good to have a possibility to use custom decoder on the whole object and not resource by resource. Location updates already work this ...
Peter Gaspar almost 5 years ago in Cumulocity IoT Device Mgmt. & Connectivity / LWM2M 1 Future consideration

Removal of “Auto observe” switch object from GUI in Cumulocity portal

“Auto observe” switch object needs to be deleted from GUI in Cumulocity 9.16 (or 10.5). This switch is located in Device Management page > Device type category > Device protocol item > any of protocols. This feature appears as we choo...
Guest almost 5 years ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Unlikely to support

LwM2M Firmware repository - fragment with the MO itself to configure individual FW updates to use one protocol over another

Orignial question: We currently have support for both CoAP and HTTP based protocols for the firmware repo, how do we configure individual firmware updates to use one protocol over another? Attached is further commentary between Elias and Cris Da...
Guest about 5 years ago in Cumulocity IoT Device Mgmt. & Connectivity / LWM2M 1 Unlikely to support

Firmware/Software mgmt: Store documents, like terms & conditions and release notes to each firmware/software

Enhance the firmware/software repository and management by adding the functionality to attach (multiple) documents to each firmware/software. Documents could be Terms & Conditions and release notes.Optionally each document can be categorized a...
Guest over 5 years ago in Cumulocity IoT Device Mgmt. & Connectivity / Software Management 1 Unlikely to support