Skip to Main Content
Cumulocity IoT Feedback Portal
ADD NEW FEEDBACK

Cumulocity IoT Device Mgmt. & Connectivity

Showing 109 of 407

LwM2M – Complete support for version 1.1

The following LwM2M 1.1 features are currently not supported by C8Y and are important to Itron: OSCORE - preferred E2E security solution by the Itron security team and a fundemental requirement for a couple of projects (water metering). Multi-inst...
Iain Mackenzie about 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 5 Future consideration

Read out a OPC UA server via the OPC UA client

I would like to read out a OPC UA server via the OPC UA client possibilities of C8y. I have several tags that I need to capture at 50 ms which is not problem. However to avoid having a lot of data, I have a trigger available to me that tells me wh...
Guest about 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

We have a customer requirement to be able to send data to Cumulocity IoT using SparkPlugB over MQTT. Is this something that could be included?

No description provided
Guest 7 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Clarification needed

LWm2m: Avoid unnecessary unavailability alarms for LwM2M device

Description: For LWm2m devices, the expected transmission interval (Required interval) is currently linked to the registration lifetime and it doesn't matter what is entered in the GUI, this value is always be overwritten by the "LwM2M Server Life...
Juergen Hahl over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 6 Planning / planned

Allow comments in LWM2M post operations

In the LWM2M post operations input field operations that will be sent to device can be edited. In the example window on the right there are comments that start with a "#" to describe the following line: # Discover all resources of Object 3300, the...
Guest almost 3 years ago in Cumulocity IoT Device Mgmt. & Connectivity / LWM2M 1 Planning / planned

Inappropriate response for error reporting during the migration of lwm2m devices

We have noticed an inappropriate response for error reporting during the migration of lwm2m devices in one of our customer tenancy. device count for migration success/failure is reported as null instead of actual count. Customer attempted to migra...
Santhosh Thakkalapally 7 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Clarification needed

select multiple devices via checkbox at bulk operations

we want to achive to execute a bulk operation for more than one devices. for that i expected to select more devices (e.g. 4) via checkbox in the appropriate dialoge. similiar to add target devcie to a group, we expect the same for "select target d...
Guest over 2 years ago in Cumulocity IoT Device Mgmt. & Connectivity 2 Future consideration

When device type is deleted remove related objects

This would help customer mange many device at one time. For example customer has 1000 child devices of one device type and after some time this device type is no longer supported. Customer has to manually remove 1000 child devices and he has to be...
Mirela Kovacevic about 2 years ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

LWM2M custom decoder for a whole object

For some objects, it is more efficient for a device to report whole object in one message. Therefore it would be good to have a possibility to use custom decoder on the whole object and not resource by resource. Location updates already work this ...
Peter Gaspar over 4 years ago in Cumulocity IoT Device Mgmt. & Connectivity / LWM2M 1 Future consideration

Download Proxy for Software / Firmware images

The IoT platform could provide a download proxy that provides access to the original download endpoint. This would: a) simplify authentication problems and b) could implement on-the-fly (delta) compression and c) could allow resuming the download ...
Nikolaus Neuerburg over 3 years ago in Cumulocity IoT Device Mgmt. & Connectivity / Device Management 0 Future consideration