Skip to Main Content
Cumulocity IoT Feedback Portal
ADD NEW FEEDBACK

Cumulocity IoT Device Mgmt. & Connectivity

Showing 95 of 374

LwM2M - Bootstrap configurations sent automatically

Problem: While connecting to the Bootstrap server, some of the configurations (Lifetime, pmin, pmax) are automatically sent to the devices, even if the were not specified during the device registration process. This could lead to problem, for inst...
Guest about 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 3 Planning / planned

"Up" button or breadcrumb for child devices in Device Management

In Device Management, and in Cockpit, it's possible to "drill down" to examine child devices, by clicking on the "Child device" link, and selecting a child device from a list. However, once you have selected a child device, there is no visual way ...
Neil C about 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

Devices in or exiting Maintenance should continue to correctly report their connection status correctly

Per SI-497717: Device Mangement's "Device Status" panel briefly but incorrectly shows "Send connection" status as "offline" when exiting Maintenance we are raising this minor bug since it apparently requires a significant overhaul to the way Maint...
Neil C about 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 2 Likely to support/improve

Automatically remove Bulkoperations Group

When we create Bulkoperations with devices over the filter funktion. Cumulocity creates a Bulkoperations Group in the background. This Groups are not deleted automatically and remain on the plattform till the Groups are deleted manuelly. When Bulk...
Guest about 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 1

Alarm Count on Tob Level (Groups) should be available regarding consistency

- alarm count is visible in every device > devicedetials > table wiht column "alarms" - also currently in 10.14 there is on top level (Group) the table with also "alarm" column. so the user would expected, that alarms are listed here (for gr...
Guest about 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 5 Unlikely to support

Generate a 'Maintenance' Event or Alarm when Maintenance is selected in Device Management

Today, the only function of the Maintenance toggle switch in Device Management is to suppress the generation of c8y_UnavailabilityAlarms when a device fails to communicate for the 'Required interval'. But there are also additional use-cases for ma...
Neil C about 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

Split Smart Groups and Groups

Dears, please split the Groups and the SmartGroups into two different Menus. Managing Groups is very difficult, if you have a lot users and a lot Smart Groups. Thanks
Guest over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 2 Likely to support/improve

Group assignment research in device management should be case insensitive

Currently group assignment research in device management is case sensitive A client of us found actual behaviour not efficient. He stated he was more productive with old version of group assignment (UI 10.6) that was case insensitive: he quickly t...
Alessandro Dalla Torre over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 2 Clarification needed

Devicelist - Registration date filter - date in future should be greyed out in popup

steps: open an devicemngt instance navigate to devicemngt > all devices list click filter registration date > popup with filter options appear choose future date (e.g. the day after today) in field "Show devices registered after" choose fute...
Guest over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 2 Unlikely to support

Cloud Fieldbus support for float32 via Modbus

At the moment, the Cloud Fieldbus feature and the Modbus Linux agent only support integer measurements. A number of Modbus devices now actually support float values (typically 32Bit IEEE-754) which currently have to be converted manually using a m...
Guest about 4 years ago in Cumulocity IoT Device Mgmt. & Connectivity 0 Unlikely to support