Skip to Main Content
Cumulocity IoT Feedback Portal
ADD NEW FEEDBACK

Cumulocity IoT Device Mgmt. & Connectivity

Showing 15

Implementation of Sorting and Filtering options for Event logs

Currently, the Event logs in Device Management application has no sorting options and also filtering options available are limited. We are proposing the implementation of the below that would enhance the UI experience and also help in troubleshoot...
Mohammed Ali Khan 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 3 Likely to support/improve

Lwm2m bulk device registration failures - Operation Status for partial success/failure

Currently we have only four status for Device Operations - Pending/Executing/Successful/Failed. However it becomes quite tricky with partial failures (or say partial success), which currently displays as 'Failed' similar to the one which is comple...
Mohammed Ali Khan 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 2 Likely to support/improve

Implementation of Sorting and Filtering options Operations under Device Control in Device Management application

Currently, the Operations under Device Control in Device Management application has no sorting options and also filtering options available are limited (based on Status) We are proposing the implementation of the below that would enhance the UI ex...
Mohammed Ali Khan 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve

Filter events based on date and time

In Device Management - Device - Events, the filtering of events is possible only based on "Date from" and "Date to". If there are lots of events on a specific day, the user has to scroll down the whole day to see the first events of the day. In ad...
Guest about 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve

Request to add device LastCommunication date field to the standard columns list in device list table

It's good to have device LastCommunication date to the standard columns list(Device Management-> All devices-> standard columns of the table AND Cookpit->Groups->Subassets ). We used to get regular customer incidents for device disconn...
Santhosh Thakkalapally 5 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve

LwM2M PSK should not be available in plaintext

The LwM2M config (including PSK ID and keys for bootstrap and server authentication) is available/displayed in plaintext through the API and UI. This is in contrast to the secure provisioning of standard device credentials (password), which cannot...
Guest 8 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve

Improvement child device view

How do I recognize the assignment to a "parent" device of a child device in the platform? If I am looking for a child device, e.g. by name, then at least I get the view in Device Management. there I can't see the assignment to the "root" device, ...
Guest over 2 years ago in Cumulocity IoT Device Mgmt. & Connectivity 0 Likely to support/improve

UI support for OPC-UA address space refresh

Situation: We have a device that is connected via OPC-UA to the tenant. Now, the address space on the south (machine) is changing. I learned already that with the help of an operation, the address space in the tenant can be updated. But this is un...
Manfred Strasser over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve

LwM2M events and alarms text placeholders

The LwM2M agent can create measurements, events, and alarms when resource values are read from or sent by an LwM2M device using additional functionalities. It seems that the text that is included in the creation of the event or alarm is a static s...
Guest 11 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve

LwM2M – C8Y should not implement queuing when a device registers with queue mode = false

For a LwM2M device, C8Y always performs queuing even if queue mode is set to false (Binding Mode: U) on registration. This can be observed by: Device successfully registers. A read (or write) is issued from the shell, but due to say a temporary lo...
Iain Mackenzie 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 3 Likely to support/improve