Skip to Main Content
Cumulocity IoT Feedback Portal
ADD NEW FEEDBACK

Cumulocity IoT Device Mgmt. & Connectivity

Showing 109

Bulk upload of multiple LWM2M object definition files

When using LWM2M every object has to be uploaded separatly to the platform. This causes a lot of repetitive work. The idea is, instead of uploading single LWM2M object definition at a time, upload multiple files at once. This would smoothen the se...
Guest almost 3 years ago in Cumulocity IoT Device Mgmt. & Connectivity / LWM2M 1 Future consideration

Remote Access over HTTP to Device UI with Configuration

Some devices have a Configuration tool on the device side which could be accessed over cumulocity with the remote access Microservice. Remote Access does not support http (443) connect. Some of the device configuration are device specific and are ...
Guest over 2 years ago in Cumulocity IoT Device Mgmt. & Connectivity / Cloud Remote Access 6 Partially supported already

LwM2M events and alarms text placeholders

The LwM2M agent can create measurements, events, and alarms when resource values are read from or sent by an LwM2M device using additional functionalities. It seems that the text that is included in the creation of the event or alarm is a static s...
Guest over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve

Request to add device LastCommunication date field to the standard columns list in device list table

It's good to have device LastCommunication date to the standard columns list(Device Management-> All devices-> standard columns of the table AND Cookpit->Groups->Subassets ). We used to get regular customer incidents for device disconn...
Santhosh Thakkalapally 11 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve

LwM2M - Standards-based Server API Support

Today, each LwM2M Server has a proprietary API interface that external systems can use for integration. This requires costly server-specific integration work and support. We understand that OMA is working on adding a standards-based Server API. Li...
Iain Mackenzie 12 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

Easier way to search for events in the LwM2M events log

When searching for logs in the events tab (either from the overall events stream in the Device Management or from the device itself), we can only search for event types such as: c8y_CBOR_DECODING_EVENT lwm2m_log c8y_LWM2MDeviceRegistration Howeve...
Laudemhir Jan Parel 12 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

LwM2M - Non-Confirmable Message Support

Current LwM2M standards require all LwM2M messages to be confirmed. Itron understands that OMA will soon be adding an option to selectively disable message confirmation. Changes to both LwM2M server and LwM2M clients will be needed to deliver non-...
Iain Mackenzie 12 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

LwM2M – Support for version 1.2

While several C8Y competing, products are supporting LwM2M version 1.2 features (AVSystems, Ioterop, Friendly Technologies...), SAG's C8Y is lagging and has not yet released LwM2M 1.2 support. The following 1.2 features are increasingly becoming i...
Iain Mackenzie 12 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

LwM2M – Complete support for version 1.1

The following LwM2M 1.1 features are currently not supported by C8Y and are important to Itron: OSCORE - preferred E2E security solution by the Itron security team and a fundemental requirement for a couple of projects (water metering). Multi-inst...
Iain Mackenzie 12 months ago in Cumulocity IoT Device Mgmt. & Connectivity 5 Future consideration

Audit log is missing device protocol XML added/deleted

In our tenant we have multiple products being developed, some of which use the same LwM2M definitions. If a user deletes/adds/modifies a LwM2M definition we have no tracking in the audit logs of who did that. Everyone on the system needs the abili...
John Fisher over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 4 Clarification needed