Skip to Main Content
Cumulocity IoT Feedback Portal
ADD NEW FEEDBACK

Cumulocity IoT Device Mgmt. & Connectivity

Showing 94 of 372

Software & configuration update operations lifecycle should include a "Locally Staged" step

In common with many industrial equipment manufacturers, our customers are cautious about over-the-air updates for devices in thier facilities. A common request is for a local approval step in the application of software updates and configuration c...
Neil C over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 3 Future consideration

Honor UI consistency by moving button for adding new OPC UA Server to top of management page for OPC UA Gateway devices

The default location for any "add XXX" functionality for c8y web interface is always top right in the "page-toolbar". However, after registering an OPC-UA gateway, the "Add Server" button on sub menu "OPC UA server" is located at the bottom of the...
Guest over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Already supported

Add OPC/UA pub/sub to the opc/UA agent

We should be able to connect the opc-ua agent to the OPC UA standard and the the whole integration between devices should work out of te box. https://www.prosysopc.com/blog/opc-ua-pubsub-explained/ So publishing information from the device should ...
Guest over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

Device tracking should update with all movement as you change the time frame

We noticed a strange behavior with the Tracking option for a device, under the Device Management application. When we reselect the date / time range from, say, “Last hour” to “Last day”, the map doesn’t seem to update to show all the movement in t...
Guest over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 3 Planning / planned

When the system language is set to Simplified Chinese, the device status time display is changed to 24 hours or the option to set the time display format is added.

When the system language is set to Simplified Chinese, in the "All devices" option of MindConnect IoT Extension, the time format of the current device connection status is changed from 12-hour system to 24-hour system, or the option that the user ...
Guest over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 5 Clarification needed

Clicking on non-device objects (like microservices) from events needs to be displayed in a separate screen, other than the device info page

Currently, clicking on non-device objects such as microservice application from events, opens the device info page for that object which is ideally not correct nor user-friendly. Issue impact? When users have large amount of assets (devices/non-de...
Mohammed Ali Khan over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 3 Clarification needed

Cloud Fieldbus UI: Validation of fragment / series names

Our Customer TT-Control has following issue: Incident: 5428979 Basically the problem of TTC is that their customers uses spaces when they define device types in holding registers. The problem results in empty reports. TTC asks if it is possible to...
Guest over 3 years ago in Cumulocity IoT Device Mgmt. & Connectivity / Cloud Fieldbus 2 Future consideration

Need hook for performing validations on JSON file in Device Protocols

Internal ticket: TTCON3G-2287 No validation is currently done when importing a device type from a JSON file in the Device Protocol view and this leads to invalid protocols. This causes issues on customer side. TTControl requests a hook to be able ...
oana velicu almost 2 years ago in Cumulocity IoT Device Mgmt. & Connectivity 3 Already supported

Optimize OPC-UA gateways' address scanning

As many of the PLC's and Yokogawa historian have vasts amounts of tags they expose the address space of their OPC-UA servers is very large. (500.000+ nodes for Yokogawa, at this point unclear how large in total). The OPC-UA gateway frequently cras...
Misja Heuveling almost 2 years ago in Cumulocity IoT Device Mgmt. & Connectivity 0 Future consideration

Display visual warning on deleting the components used in a profile and a warning that a profiles component does not exist

Device profiles are observed to hold the deleted files/configurations without any notification/warning to the user. This, in-turn, causes unnecessary confusions/issues for the devices assigned with such device profiles. It is highly desirable that...
Mohammed Ali Khan almost 2 years ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration