Easier way to search for events in the LwM2M events log

When searching for logs in the events tab (either from the overall events stream in the Device Management or from the device itself), we can only search for event types such as: c8y_CBOR_DECODING_EVENT lwm2m_log c8y_LWM2MDeviceRegistration Howeve...
Laudemhir Jan Parel 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

LwM2M - Non-Confirmable Message Support

Current LwM2M standards require all LwM2M messages to be confirmed. Itron understands that OMA will soon be adding an option to selectively disable message confirmation. Changes to both LwM2M server and LwM2M clients will be needed to deliver non-...
Iain Mackenzie 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

Improvement child device view

How do I recognize the assignment to a "parent" device of a child device in the platform? If I am looking for a child device, e.g. by name, then at least I get the view in Device Management. there I can't see the assignment to the "root" device, ...
Guest over 2 years ago in Cumulocity IoT Device Mgmt. & Connectivity 0 Likely to support/improve

LwM2M – Support for version 1.2

While several C8Y competing, products are supporting LwM2M version 1.2 features (AVSystems, Ioterop, Friendly Technologies...), SAG's C8Y is lagging and has not yet released LwM2M 1.2 support. The following 1.2 features are increasingly becoming i...
Iain Mackenzie 7 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

LwM2M – Complete support for version 1.1

The following LwM2M 1.1 features are currently not supported by C8Y and are important to Itron: OSCORE - preferred E2E security solution by the Itron security team and a fundemental requirement for a couple of projects (water metering). Multi-inst...
Iain Mackenzie 7 months ago in Cumulocity IoT Device Mgmt. & Connectivity 5 Future consideration

UI support for OPC-UA address space refresh

Situation: We have a device that is connected via OPC-UA to the tenant. Now, the address space on the south (machine) is changing. I learned already that with the help of an operation, the address space in the tenant can be updated. But this is un...
Manfred Strasser over 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve

Read out a OPC UA server via the OPC UA client

I would like to read out a OPC UA server via the OPC UA client possibilities of C8y. I have several tags that I need to capture at 50 ms which is not problem. However to avoid having a lot of data, I have a trigger available to me that tells me wh...
Guest 7 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

LwM2M events and alarms text placeholders

The LwM2M agent can create measurements, events, and alarms when resource values are read from or sent by an LwM2M device using additional functionalities. It seems that the text that is included in the creation of the event or alarm is a static s...
Guest 11 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve

Audit log is missing device protocol XML added/deleted

In our tenant we have multiple products being developed, some of which use the same LwM2M definitions. If a user deletes/adds/modifies a LwM2M definition we have no tracking in the audit logs of who did that. Everyone on the system needs the abili...
John Fisher about 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 4 Clarification needed

Export/Import Device Management->Device protocol XML resource mapping

If a user configures a bunch of Lwm2m XMLs and links each resource with MEAs or custom actions inside one tenant, this work cannot be easily exported to another tenant and thus requires manually setting all of this again.
John Fisher about 1 year ago in Cumulocity IoT Device Mgmt. & Connectivity 2 Future consideration