device-info page: 1000 events UI limitation should be removed

SAG R&D confirmed that in the current version the maximum of 1000 events are limited as per the UI. Having a hard limit on 1K means that often what is default view for the user will appear broken as not all events in the default timeframe can ...
oana velicu over 2 years ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Partially supported already

Smart rule: On measurement explicit threshold create alarm

When creating a Smart Rule "On measurement explicit threshold create alarm" the following changes shall be made: The switch "Enabled" in the upper part is not working when saving the smart rule. When saved it needs to be manually switched on (in t...
oana velicu over 2 years ago in Cumulocity IoT Streaming Analytics (inc. Apama) / Smart rules 1 Future consideration

Email Alarm Creation - auto completion needed for the alarm type

(Note for TTControl: Internal ticket 144) When creating the "*On alarm send e-mail*" (from "*Smart Rules*" side panel), the "*On Alarm matching*" field should show the list of "Alarm Type" (from the "Alarms / Events" panel in the "*Data Explorer*"...
oana velicu over 2 years ago in Cumulocity IoT Platform Services / Platform Management 1 Future consideration

Improve Graph representation on Cumulocity and APAMA

Proposal when the data is not grouped , we could use line with markers. every markers correspond to the available data. if there is no marker, this would mean that the line is "just" a point to point connection. when the data is grouped by. the cl...
oana velicu over 2 years ago in Cumulocity IoT Cockpit and WebSDK / Dashboarding 2 Unlikely to support

Added Timespan for alarm fragment

Hi Team, a client has reported that his widget didn't show the duration correctly. It should be fixed/updated. Our Idea: After clearing an existing alarm, should the Timespan should be shown correctly. Test-Informations: There is only one minute b...
Guest over 2 years ago in Cumulocity IoT Cockpit and WebSDK 1

Datapoint following a logical scheme

the "Add datapoint" dialog we noticed that the sorting is random (though constant) and the colors of the datapoints change every time. The changing colors pose a problem if customers decide not to use the datapoint library and two people work on a...
Guest almost 5 years ago in Cumulocity IoT Cockpit and WebSDK / Dashboarding 5 Already supported

Additional aggregation intervals

When our customers analyse data via the data explorer, they are always complaining about the large jump in aggregation between 1 minute and 1 hour. Something like 5 or 10 minutes would be a good intermediate average for analysis
Guest almost 5 years ago in Cumulocity IoT Platform Services / Runtime Services 1 Future consideration

Support different network interfaces on Edge

"separate" the edge in the data ingestion part and the application server part. Both components should be in different network segment We are very strictly implementing the OSI95 model. Thereby the PLC's will be in Layer 2, C8Y Data ingestion woul...
Andrej Schreiner over 2 years ago in Cumulocity IoT Edge 0

UseDNS flag to increase SSH login speed

I have an improvement suggestion for the edge releases. If the edge is deployed without any DHCP and DNS server available the SSH login is painfully slow. In an edge case this scenario is pretty common. If you could set UseDNS to no in the SSH c...
Andrej Schreiner about 5 years ago in Cumulocity IoT Edge 0

OAuth2 authorization response should properly handled error information

Hi, When using an external OAuth2 authorization server in Cumulocity the authorization server may deny access or fail to whatever reason the authorization request. In this case, according to RFC 6479, the authorization sever will redirect the user...
Florian Huber over 2 years ago in Cumulocity IoT Platform Services / Authentication & Authorisation 0 Planning / planned