LwM2M - Non-Confirmable Message Support

Current LwM2M standards require all LwM2M messages to be confirmed. Itron understands that OMA will soon be adding an option to selectively disable message confirmation. Changes to both LwM2M server and LwM2M clients will be needed to deliver non-...
Iain Mackenzie 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

LwM2M – Support for version 1.2

While several C8Y competing, products are supporting LwM2M version 1.2 features (AVSystems, Ioterop, Friendly Technologies...), SAG's C8Y is lagging and has not yet released LwM2M 1.2 support. The following 1.2 features are increasingly becoming i...
Iain Mackenzie 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

LwM2M – Complete support for version 1.1

The following LwM2M 1.1 features are currently not supported by C8Y and are important to Itron: OSCORE - preferred E2E security solution by the Itron security team and a fundemental requirement for a couple of projects (water metering). Multi-inst...
Iain Mackenzie 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 5 Future consideration

Association templates, to link device features (measurements, alarms etc.) to Digital Twin Assets

The Digital Twin Manager is a powerful tool for defining asset "type" data models. However, once an asset has been defined, the intuition and value of what a device represents begins to change... Really, a device now only represents and endpoint i...
Neil C about 1 year ago in Cumulocity IoT Digital Twin Manager 1 Future consideration

Read out a OPC UA server via the OPC UA client

I would like to read out a OPC UA server via the OPC UA client possibilities of C8y. I have several tags that I need to capture at 50 ms which is not problem. However to avoid having a lot of data, I have a trigger available to me that tells me wh...
Guest 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

To have editable UI option to change the Administrator's username of tenant owner via. management tenancy

Issue: Currently the Adminstrator's username field of tenant owner is non-editable on management UI, which causes problems when there is a need to change the tenant owner. Workaround: Request Software AG team to change it via. backend everytim...
Mohammed Ali Khan over 1 year ago in Cumulocity IoT Platform Services / Platform Management 0 Future consideration

Export/Import Device Management->Device protocol XML resource mapping

If a user configures a bunch of Lwm2m XMLs and links each resource with MEAs or custom actions inside one tenant, this work cannot be easily exported to another tenant and thus requires manually setting all of this again.
John Fisher 12 months ago in Cumulocity IoT Device Mgmt. & Connectivity 2 Future consideration

Bulk upload of multiple LWM2M object definition files

When using LWM2M every object has to be uploaded separatly to the platform. This causes a lot of repetitive work. The idea is, instead of uploading single LWM2M object definition at a time, upload multiple files at once. This would smoothen the se...
Guest over 2 years ago in Cumulocity IoT Device Mgmt. & Connectivity / LWM2M 1 Future consideration

Log User deleting folders by drag and drop

User can drag and drop folders, included sub folders, around all hierarchy. if they do it in the main folder, they will not see that group anymore. you need to log who is doing this kind of actions to solve arising issue.
Guest almost 2 years ago in Cumulocity IoT Platform Services / Data at Rest 0 Future consideration

Usage Statistics App - Default Configuration

Overview: The configuration for the usage statistics application should be inherited from a tenant property. This would enable metrics and thresholds to be added by default, rather than having to be added by the end user. In addition, this would e...
Tal Dunne 9 months ago in Cumulocity IoT SaaS Enablement 0 Future consideration