Skip to Main Content
Cumulocity IoT Feedback Portal
ADD NEW FEEDBACK

All feedback

Showing 372 of 372

Lwm2m bulk device registration failures - Operation Status for partial success/failure

Currently we have only four status for Device Operations - Pending/Executing/Successful/Failed. However it becomes quite tricky with partial failures (or say partial success), which currently displays as 'Failed' similar to the one which is comple...
Mohammed Ali Khan 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 2 Likely to support/improve

Implementation of Sorting and Filtering options Operations under Device Control in Device Management application

Currently, the Operations under Device Control in Device Management application has no sorting options and also filtering options available are limited (based on Status) We are proposing the implementation of the below that would enhance the UI ex...
Mohammed Ali Khan 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve

Improvements to Availability menu in Device Management application

The Availability menu under Device Management application has been pretty much stagnant in terms of improvements for a long time now. Currently it only displays the availability data based on critical Alarm filter with no other filtering options a...
Mohammed Ali Khan 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Future consideration

To be able to edit the custom column added in the All devices page of Device Management

Currently when a user adds any custom column using "header" and "fragement_path" in the All devices page, it is found that those columns are non-editable and can only be deleted. Also the user is not able to view what values were entered for 'head...
Mohammed Ali Khan 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 4 Planning / planned

To have an option to delete multiple device assets at once from the UI

Currently, the Cumulocity UI only offers an option to delete one device at a time which becomes quite tedious if bulk devices needs to be removed. With bulk device registration option in place, it makes sense to have an option for bulk deletion of...
Mohammed Ali Khan 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 2 Future consideration

Notifications 2.0 - Add the ability to filter on Managed Object fragments

Enhance the Notifications 2.0 subscription filter to enable filtering on managed object fragments such as device type and to use wild cards in filters, such as “c8y_temp*”, to match everything starting with “c8y_temp”.
Iain Mackenzie 6 months ago in Cumulocity IoT Platform Services 0

To be able to identify the Tenant primary Admin from the list of users in the Administration application

Currently there is no means to identify the Tenant primary admin from the other admins in the tenancy. All admins are displayed in the similar fashion and It creates a sense of confusion to differentiate between the primary admin and other admins....
Mohammed Ali Khan 6 months ago in Cumulocity IoT Platform Services / Platform Management 2 Clarification needed

Option to cancel Pending operations in bulk from Device Control Screen

Currently pending operations queued for devices can only be cancelled one at a time, which becomes quite tedious if there is huge set of wrong pending operations that is queued and needs cancellation. User can possibly set wrong operations for a d...
Mohammed Ali Khan 6 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Unlikely to support

LwM2M: Change implementation to not count connector as device

Currently (c8y 10.16) LwM2M creates a "LwM2M Connector Device" which is available in the All Devices list and has the c8y_IsDevice fragment. This fragment is actually a key element for device-count in tenant-statistics, so when LwM2M is added on a...
Christoph Marschall 8 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Planning / planned

LwM2M PSK should not be available in plaintext

The LwM2M config (including PSK ID and keys for bootstrap and server authentication) is available/displayed in plaintext through the API and UI. This is in contrast to the secure provisioning of standard device credentials (password), which cannot...
Guest 8 months ago in Cumulocity IoT Device Mgmt. & Connectivity 1 Likely to support/improve